Toyota Corolla (E120) 2002–2008 Repair Manual / Diagnostics / Sfi system / Oxygen sensor circuit no activity
detected
Toyota Corolla (E120): Oxygen sensor circuit no activity detected
Dtc p0134 oxygen sensor circuit no activity detected (bank 1 sensor 1)
Other materials:
Inspection procedure
1 Check ignition or starter switch assy
Check the ignition switch, as shown in the illustration and
table.
Standard:
2 Check fuse (ecu–b)
Remove the fuse from the instrument panel j/b.
check the continuity of the fuse.
Standard: continuity
3 Check relay (m ...
Circuit description
The vapor pressure sensor, vsv for canister closed valve (ccv), vsv for
pressure switching valve are used
to detect abnormalities in the evaporative emission control system.
The ecm decides whether there is an abnormality in the evaporative emission
control system based on the
vapor pressur ...