Toyota Corolla (E120) 2002–2008 Repair Manual / Diagnostics / Sfi system / Oxygen sensor circuit no activity detected

Toyota Corolla (E120): Oxygen sensor circuit no activity detected

Dtc p0134 oxygen sensor circuit no activity detected (bank 1 sensor 1)

Share this page:

Other materials:

On–vehicle inspection
Notice: ”cold” and ”hot” in these sentences express the temperature of the coils themselves. ”Cold” is from –10 c (14 f) to 50 c (122 f) and ”hot” is from 50 c (122 f) to 100 c (212 f). 1. Inspect ignition coil (with igniter) and spark test  confirm dtc. Notice: ...

Message Settings
1 Display the “Phone/Message Settings” screen. 2 Select “Messaging Settings”. 3 Select the desired item to be set. 1 Set automatic message transfer on/off. 2 Set automatic message readout on/off. 3 Set the SMS/MMS notification popup on/off. 4 Set the e-mail notification popup on/off. 5 ...

Inspection procedure
Hint: start the inspection from step 1 in case of using the hand–held tester and start from step 2 in case of not using the hand–held tester. 1 Perform active test by hand–held tester(abs motor relay) Check the operation sound of the abs motor individually when operaing it with the ...