Toyota Corolla (E120) 2002–2008 Repair Manual / Diagnostics / Sfi system / Oxygen sensor circuit no activity detected

Toyota Corolla (E120): Oxygen sensor circuit no activity detected

Dtc p0134 oxygen sensor circuit no activity detected (bank 1 sensor 1)

Share this page:

Other materials:

Inspection procedure
Hint: read freeze frame data using the hand–held tester or the obd ii scan tool. Freeze frame data records the engine conditions when a malfunction is detected. When troubleshooting, it is useful for determining whether the vehicle was running or stopped, the engine was warmed up or not, th ...

Brake
On–vehicle inspection 1. Inspect brake line pipes and hoses Hint: work in a well–lighted area. Turn the front wheels fully to the right or left before begining.  check all the brake lines and hoses for: damage wear deformation cracks corrosion leaks bends twi ...

Inspection procedure