Toyota Corolla (E120): On–vehicle inspection

1. Check clutch start system

  1. Check that the engine does not start when the clutch pedal is released.
  2.  check that the engine starts when the clutch pedal is fully depressed.

If necessary, replace the clutch start switch assy.

    Share this page:

    Other materials:

    Circuit description
    Refer to dtc p0130 Dtc no. Dtc detecting condition Trouble area P0134 After engine is warmed up, heated oxygen sensor (bank 1 sensor 1) output does not indicate rich (greater than 0.45 V) even once when conditions (a), (b), (c), (d) and (e) continue for ...

    Oxygen sensor monitor (front and rear o2s system)
    Preconditions The monitor will not run unless: mil is off  drive pattern  connect the obd ii scan tool to the dlc3 to check monitor status and preconditions.  Start the engine and allow it to idle for 2 minutes or more.  Drive the vehicle at 25 mph ...

    Inspection procedure
    1 Prepare for inspection Disconnect the negative (–) terminal cable from the battery, and wait at least for 90 seconds.  remove the horn button assy .  disconnect the connector of the instrument panel passenger airbag assy .  disconnect the connector of the front sea ...