Toyota Corolla (E120): Open in d squib (2nd step) circuit

Share this page:

Other materials:

On–vehicle inspection
1. Inspect refrigerant pressure with manifold gauge set  this is a method in witch the trouble is located by using a manifold gauge set. Read the manifold gauge pressure when the these conditions are established. Test conditions: temperature at the air inlet with the switch set ...

Inspection procedure
1 Inspect shift solenoid valve(s2) Remove the shift solenoid valve s2.  measure the resistance according to the value(s) in the table below. Standard: Connect the positive (+) battery lead to the solenoid connector terminal, and the negative (–) battery lead to the so ...

Check short circuit
If the wire harness is ground shorted as shown in fig. 5, Locate the section by conducting a resistance check with the body ground in step (b). Check the resistance with the body ground.  Disconnect connectors a and c and measure the resistance between terminals 1 and 2 ...