Toyota Corolla (E120): On–vehicle inspection

1. Inspect turn signal flasher relay circuit

  1. Disconnect the connector from the turn signal flasher relay and inspect the connector on wire harness side as shown in the chart.

Standard:

  1. Connect the connector to the turn signal flasher and inspect the wire harness side connector from the back side as shown in the chart.

Standard:

2. Inspect daytime running light relay

2. Inspect daytime running light relay

  1. Connect the connector to the daytime running light relay and inspect the wire harness side connector from the back side as shown in the table below.

Standard:

*1: Usa only.

*1: Usa only.

3. Illuminated entry system operation check

  1.  the illuminated entry system controls the room lamp assy no.1.
  2.  check that the lamps come on when any of the doors are opened. Then check that the lamps fade out under any one of the following conditions:
  1.  15 seconds after all the doors are closed.
  2.  The ignition switch is turned to the on position with all the doors closed.
  3.  All the doors are closed and locked.
  1.  check that the lamps stay on for at least 15 seconds after opening any of the doors before fading out as described in (b). Then check that the lamps fade out in 15 seconds after closing all the doors.
  2.  check that the lamps come on when opening any of the doors and fade out when closing and locking all the doors or turning the ignition switch to the acc or on position.

4. Battery saver operation check

  1.  remove the ignition key and close all the doors.
  2.  open any door to turn the room light on, and leave it open. Check that the light goes off after approx.

    20 Minutes.

  3.  after the room light goes off, close the door.
  4.  open any door to turn the room light on, and then open another door. Check that the room light goes off after approx. 20 Minutes after opening the doors.
  5.  close all the doors. With the ignition key inserted, open any door to turn the room light on, and then remove the ignition key. Check that the room light goes off after approx. 20 Minutes.
    Share this page:

    Other materials:

    Inspection procedure
    1 Check ignition or starter switch assy Check the ignition switch, as shown in the illustration and table. Standard: 2 Check fuse (ecu–b) Remove the fuse from the instrument panel j/b.  check the continuity of the fuse. Standard: continuity 3 Check relay (m ...

    Replacement
    Hint: components: 1. Precaution 2. Disconnect battery negative terminal 3. Remove horn button assy Place the front wheels facing straight ahead.  using a torx socket wrench (t30), loosen the 2 torx screws until the groove along the screw circumference catches on the screw ca ...

    Transmission valve body assy (atm)
    Replacement 1. Remove engine under cover lh 2. Drain automatic transaxle fluid  remove the drain plug, gasket and drain atf.  install a new gasket and drain plug. Torque: 17.5 Nvm (178 Kgf·cm, 13 ft·lbf) 3. Remove automatic transaxle oil pan sub–assy Remove the 18 ...