Inspection procedure
1 Inspect fuse(stop)
Turn the ignition switch to off.
remove the stop fuse from the instrument panel j/b.
check continuity of the stop fuse.
Ok: continuity
2 Inspect stop lamp switch assy
Disconnect the stop lamp switch assy connector.
check continuity betw ...
Inspection
1. Spark plug
Notice:
never use a wire brush for cleaning.
Never attempt to adjust the electrode gap on used
spark plug.
Spark plug should be replaced every 192,000 km
(120,000 miles).
Clean the spark plugs.
Air pressure: below 588 kpa (6.0 Kg/cm2, 85 psi)
duration: 20 sec ...
Circuit description
When driving uphill under cruise control, in order to reduce the number of
shifting due to on–off overdrive
operation and to provide smooth driving, when down shifting in the
electronically controlled transmission occurs,
a signal to prevent upshift until the end of the uphill slope is sent fr ...