Toyota Corolla (E120): Inspection procedure
1 Inspect shift solenoid valve(s2)
- Remove the shift solenoid valve s2.
- measure the resistance according to the value(s) in the table below.
Standard:
- Connect the positive (+) battery lead to the solenoid connector terminal, and the negative (–) battery lead to the solenoid body for checking the solenoid valve operation.
Standard: the solenoid makes an operating noise.
2 Inspect transmission valve body assy(see chapter 2 in the problem symptoms table) (
Repair or replace automatic transaxle assy
Other materials:
Registering a Bluetooth® audio player for the first time
To use the Bluetooth® Audio, it is necessary to register an audio player with
the system.
Once the player has been registered, it is possible to use the Bluetooth® Audio.
For details about registering a Bluetooth® device
1 Turn the Bluetooth® connection setting of your audio player on.
2 P ...
Evap monitor (vacuum pressure monitor)
Notice:
a cold soak must be performed prior to conducting the drive pattern to complete
the internal pressure
readiness monitor.
Cold soak preconditions
The monitor will not run unless:
mil is off.
Fuel level is approximately 1/2 to 3/4.
Altitude is 7800 feet (2400 m) or less.
...
Ecu power source circuit
Circuit description
This circuit provides power to operate the tvip ecu.
Wiring diagram
Inspection procedure
1 Check fuse (ecu–b)
Remove the fuse from the instrument panel j/b.
check the continuity of the fuse.
Standard: continuity
2 Check tvip ecu
Disconnect ...