Toyota Corolla (E120): Inspection

1. Spark plug

Notice

:

  • never use a wire brush for cleaning.
  • Never attempt to adjust the electrode gap on used spark plug.
  • Spark plug should be replaced every 192,000 km (120,000 miles).

  1. Clean the spark plugs.

    Air pressure: below 588 kpa (6.0 Kg/cm2, 85 psi) duration: 20 seconds or less

  1. Check the spark plug for thread damage and insulator damage.

Hint

: if abnormal, replace the spark plug.

Recommended spark plug: sk16r11 (denso made)
ifr5a11 (ngk made)

  1. Check the spark plug electrode gap.

    Electrode gap: 1.1 Mm (0.043 In.)

2. Crank position sensor no.1

  1.  using an ohmmeter, measure the resistance between terminals.

Resistance:
at cold 835 – 1,400 w
at hot 1,060 – 1,645 w

N

otice

: ”cold” and ”hot” on the table express the temperature of the coils themselves. ”Cold” is from –10 c (14 f) to 50 c (122 f) and ”hot” is from 50 c (122 f) to 100 c (212 f).

Hint

: if the resistance is not as specified, replace the crank position sensor no. 1.

3. Crank position sensor

  1.  using an ohmmeter, measure the resistance between terminals.

Resistance:
at cold 1,630 – 2,740 w
at hot 2,065 – 3,225 w

Notice

: ”cold” and ”hot” on the table express the temperature of the coils themselves. ”Cold” is from –10 c (14 f) to 50 c (122 f) and ”hot” is from 50 c (122 f) to 100 c (212 f).

Hint

: if the resistance is not as specified, replace the crank position sensor.

4. Ignition relay

  1. Continuity inspection.
  1. Using an ohmmeter, check that continuity exists between each terminal.

    Specified condition: between terminal 1 and 2 continuity between terminal 3 and 5 no continuity

  2.  using an ohmmeter, check that continuity exists between terminals 3 and 5 when the battery voltage is applied across terminals 1 and 2.
    Share this page:

    Other materials:

    Vehicle information
    This screen can be used to display the fuel consumption. “Trip Information” or “Past Record” screen Press “CAR” to display the “Trip Information” or “Past Record” screen. Fuel consumption ■ Trip information If the “Trip Information” screen does not appear, select ...

    Oxygen / af sensor heater monitor
    Preconditions The monitor will not run unless: mil is off  drive pattern  connect the obd ii scan tool to the dlc3 to check monitor status and preconditions.  Start the engine and allow it to idle for 9 minutes.  Drive the vehicle at 25 mph (40 km ...

    Circuit description
    When a misfire occurs in the engine, hydrocarbons (hc) enter the exhaust in high concentrations. If this hc concentration is high enough, there could be an increase in exhaust emissions levels. High concentrations of hc passing through the catalyst also cause to temperature of the catalyst to ...