Toyota Corolla (E120): Refrigerant
Other materials:
Fuel pump shut off system
To minimize the risk of fuel leakage when the engine stalls or when an airbag
inflates upon collision, the fuel pump shut off system stops the supply of fuel
to the engine.
Follow the procedure below to restart the engine after the system is activated.
► Vehicles without a smart key syst ...
Evap monitor (vacuum pressure monitor) (continued)
Preconditions
The monitor will not run unless:
mil is off.
Fuel level is approximately 1/2 to 3/4.
Altitude is 7800 feet (2400 m) or less.*
Engine coolant temperature (ect) is between 40°f and 95°f (4.4 °C and 35
°C).
Intake air temperature (iat) is between 40°f and 95 ...
Inspection procedure
1 Inspect terminal voltage(od – body ground)
Disconnect the cruise control ecu connector.
turn the ignition switch to the on position.
measure the voltage between terminal od of cruise control
ecu and body ground.
Standard:
2 Inspect terminal voltage(od1 – bod ...