    Evap monitor (vacuum pressure monitor)
    Notice: a cold soak must be performed prior to conducting the drive pattern to complete the internal pressure readiness monitor. Cold soak preconditions The monitor will not run unless: mil is off. Fuel level is approximately 1/2 to 3/4. Altitude is 7800 feet (2400 m) or less. ...

    Fuel pump shut off system
    To minimize the risk of fuel leakage when the engine stalls or when an airbag inflates upon collision, the fuel pump shut off system stops the supply of fuel to the engine. Follow the procedure below to restart the engine after the system is activated. ► Vehicles without a smart key syst ...

    Inspection