Toyota Corolla (E120): Initialization
1. Reset memory
Caution
: perform the reset memory (at initialization) when replacing the automatic transaxle assy, engine assy or ecm.
Notice
: hand–held tester only
- Turn the ignition switch off.
- connect the hand–held tester to the dlc3.
- turn the ignition switch to the on position.
- perform the reset memory procedure from the engine menu.
Caution
: after performing the reset memory, be sure to perform the road test described earlier.

Other materials:
Circuit description
The srs warning light is located on the combination meter.
When the srs is normal, the srs warning light lights up for approx. 6 Seconds
after the ignition switch is
turned from the lock position to on position, and then turns off automatically.
If there is a malfunction in the srs, the srs ...
Inspection procedure
1 Check p squib circuit(airbag sensor assy center – instrument
panel passenger airbag assy)
Disconnect the negative (–) terminal cable from the battery,
and wait at least for 90 seconds.
disconnect the connector between the airbag sensor
assy center and the instrument panel ...
Inspection procedure
1 Check security indicator light
Set the system in 30 seconds after filliping the security indicator to
check if the alarm is triggered.
2 Check glass breakage sensor ecu (glass breakage sensor)
Check the continuity and voltage of the glass breakage
sensor ecu, as shown in th ...


