Toyota Corolla (E120) 2002–2008 Repair Manual / Diagnostics / Toyota vehicle intrusion protection system / Hazard warning switch circuit / Inspection procedure
Toyota Corolla (E120): Inspection procedure
1 Check hazard warning signal switch assy

- Check the hazard warning switch continuity, as shown in the illustration and table.
Standard:



2 Check turn signal flasher assy


3 Check wire harness (tvip ecu turn signal flasher)

- Disconnect the tvip ecu and turn signal flasher connectors.
- check the continuity between the terminals of the tvip ecu and turn signal flasher connectors, as shown in the illustration and table.
Standard:



4 Check wire harness (hazard warning switch body ground)

- Disconnect the hazard warning switch connector.
- check the continuity between the terminal of the hazard warning switch connector and the body ground, as shown in the illustration and table.
Standard:



Check and replace tvip ecu
Other materials:
Replacement
Hint: components:
1. Precaution
2. Disconnect battery negative terminal
3. Remove front door scuff plate rh
4. Remove rear door scuff plate rh
5. Remove front door opening trim rh
6. Remove rear door opening trim rh
7. Remove lap belt outer anchor cover
8. Remove center pillar garnis ...
Symptom confirmation and diagnostic trouble code
Hint:
the diagnostic system in corolla has various functions. The first
function is the diagnostic trouble
code (dtc) check, in which a malfunction in the signal circuits to the ecu
is stored in code form in
the ecu memory. Another function is the input signal check, which checks if
...
Removal & installation and disassembly & reassembly
1. Remove oxygen sensor
Remove a clip and tear off the floor mat.
disconnect a oxygen sensor connector.
Remove the oxygen sensor.
2. Remove tail pipe assy
Remove 2 bolts, 2 springs and tail pipe assy.
3. Remove floor panel brace front