Malfunction in clock
Wiring diagram Inspection procedure 1 Inspect fuse Check the continuity in cig fuse.  check the continuity in dome fuse. 2 Inspect harness or connector Check voltage.  Remove the clock assy with connector still connected.  Measure voltage between ter ...

Removal and installation of fuel control parts
Place for removing and installing of fuel system parts  work in a place with good air ventilation and without anything flammable such as welder, grinder, drill, electric motor or stove in the surroundings.  Never work in a place such as a pit or nearby a pit, as there is a ...

Inspection procedure
1 Inspect park/neutral position switch assy Disconnect the park/neutral position switch connector.  measure resistance according to the value(s) in the table below when the shift lever is moved to each position. Standard: 2 Check harness and connector(park/neutral position ...