Toyota Corolla (E120): Inspection

1. Inspect sliding roof limit switch

  1. Inspect the sliding roof limit switch continuity.

Standard:

If the continuity is not as specified, replace the switch.

If the continuity is not as specified, replace the switch.

2. Inspect sliding roof drive gear sub–assy

  1. Connect the positive (+) lead from the battery to terminal 2 and the negative (–) lead to terminal 1, and check that the motor turns clockwise (moves to the close side).

  1. Reverse the polarity, check that the motor turns counterclockwise (moves to the open side).

If the operation is not as specified, replace the motor.

3. Inspect sliding roof motor circuit breaker

  1. With the sliding roof in the fully opened position, hold the sliding roof switch in the ”open” side and check that there is circuit breaker operating noise within 10 to 60 seconds.

  1. With the sliding roof in the fully opened position, hold the sliding roof switch in the ”close” side and check that the sliding roof begins to close within 60 seconds.

If the operation is not as specified, replace the motor.

4. Inspect power main relay

  1. Remove the power window relay from the instrument panel j/b.
  2.  inspect the power window relay.

Standard:

If the result is not as specified, replace the relay.

If the result is not as specified, replace the relay.

    Share this page:

    Other materials:

    Side mudguard sub–assy lh
    Replacement Hint: use the same procedures for the rh side and lh side. 1. Remove side mudguard sub–assy lh Using a clip remover, remove the 8 retainers and 9 clips.  using a moulding remover, remove the mudguard. 2. Install side mudguard sub–assy lh Install the mudgu ...

    Drive shaft / propeller shaft
    Preparation Sst Recomended tools Equipment Lubricant ...

    Circuit description
    In the diagram below, when the engine is cranked, current flows from terminal st2 of the ignition switch to the starter relay coil and also current flows to terminal sta of the ecm (sta signal). When the sta signal and ne signal are input to the ecm, tr is turned on, current flows to the c ...