Toyota Corolla (E120): Floor shift shift lever assy

Share this page:

Other materials:

Inspection
1. Thermostat Hint: the thermostat is numbered with the valve opening temperature. Immerse the thermostat in water and gradually heat the water.  check the valve opening temperature. Valve opening temperature: 80 to 84 c (176 to 183 f) Hint: if the valve opening temperatur ...

Inspection
1. Charcoal canister assy Visually check the charcoal canister for cracks or damage. Inspect the charcoal canister operation.  Plug the vent port with the cap.  While holding the purge port closed, blow air (1.76 Kpa, 18 gf/cm2, 0.26 Psi) into the evap port and ...

Inspection procedure
Hand–held tester: 1 Perform active test by hand–held tester(operation of circuit opening relay) Connect the hand–held tester to the dlc3.  turn the ignition switch on and push the hand–held tester main switch on.  select the item ”diagnosis / enhanced obd ii / active ...