Toyota Corolla (E120) 2002–2008 Repair Manual / Diagnostics / Supplemental restraint system / Open in p/t (rh) circuit / Circuit description
Toyota Corolla (E120): Circuit description
The p/t squib circuit (rh) consists of the airbag sensor assy center and seat belt pretensioner (rh).
It causes the srs to deploy when the srs deployment conditions are satisfied.
Dtc b0131/64 is recorded when an open is detected in the p/t squib (rh) circuit.

Wiring diagram
Other materials:
Inspection procedure
Hint:
if different dtcs related to different systems that have terminal e2
as the ground terminal are output
simultaneously, terminal e2 may be open.
If dtc p0441 (purge flow), p0446 (vsv for ccv), p0451, p0452 or p0453
(evaporative pressure
sensor) is output with dtc p0442 or p0456, ...
Circuit description
The vapor pressure sensor, vsv for canister closed valve (ccv), vsv for
pressure switching valve are used
to detect abnormalities in the evaporative emission control system.
The ecm decides whether there is an abnormality in the evaporative emission
control system based on the
vapor pressur ...
Purpose of the readiness tests
The on–board diagnostic (obd ii) system is designed to monitor the
performance of emission–related
components and report any detected abnormalities in the form of diagnostic
trouble codes
(dtcs). Since the various components need to be monitored during different
driving condition ...